Skip to content

Data Centre Colocation

Move out of the server room, into Interactive Port Melbourne.

Your server room is a liability. Power outages, cooling failures, and security gaps put your business at risk. We colocate your infrastructure at Interactive's enterprise-grade facility—and because our office is in the same building, we can have hands on your hardware in minutes, not hours.

$142,000

average cost of 1 hour of downtime for mid-sized businesses

99.982%

Tier III uptime standard (Uptime Institute)

64%

reported cost savings vs on-prem over 3 years

$6.81B

Australian data centre market, 2024

Sources: Gartner, Uptime Institute, and IDC Australia data centre market research, 2024.

Why We're Different

Our office is in the same building as your servers.

Most MSPs outsource colocation to facilities across town. When you need physical access, you wait hours for a third-party technician—and pay $75–150/hour for the privilege.

Communicat's office sits inside Interactive's Port Melbourne data centre. When something needs physical attention, our engineers walk downstairs. Not the next suburb—downstairs.

  • Under 5 minutes during business hours

    No third-party remote hands queues. No per-incident fees. Just our engineers, on your hardware, fast.

  • Our engineers, not third-party

    The same team that manages your IT does the physical work. Full context, no handoffs.

  • ISO 27001 & SOC 2 certified

    Interactive's facility meets the highest security standards—including APRA CPS 234 for regulated industries.

  • Port Melbourne location

    Close to Melbourne CBD with carrier-neutral connectivity and cloud on-ramps to AWS, Azure, and GCP.

Server Room vs Colocation

Your server room is a business risk

That cupboard with the blinking lights and whirring fans? It's one power surge, cooling failure, or after-hours break-in away from taking your business offline.

Power Redundancy
Your server room
Single utility feed, maybe a UPS
Colocation
N+1 UPS, dual feeds, diesel generators
Cooling
Your server room
Split system or portable AC unit
Colocation
Precision cooling with N+1 redundancy
Physical Security
Your server room
Door lock, maybe a camera
Colocation
Biometric access, mantrap, 24/7 guards, CCTV
Fire Suppression
Your server room
Standard sprinklers (destroys equipment)
Colocation
VESDA + gas suppression (equipment safe)
Connectivity
Your server room
Single ISP, maybe backup 4G
Colocation
20+ carriers, dedicated fibre options
Compliance
Your server room
Self-assessed, no certifications
Colocation
ISO 27001, SOC 2, PCI DSS, APRA ready
Uptime SLA
Your server room
Best effort (no guarantee)
Colocation
99.982%+ with financial SLA
Scalability
Your server room
Limited by office space
Colocation
1RU to cages, scale as needed
Capital Cost
Your server room
High upfront (UPS, cooling, fit-out)
Colocation
Low (just your hardware)
Physical Access
Your server room
Complete physical access
Colocation
Our office in same building—minutes not hours

What's Included

Enterprise infrastructure you couldn't afford to build

  1. 01

    Rack Space

    From 1RU to full 42RU cabinets and private cages. Standard 600mm or 800mm wide cabinets with rear cable management and growth-adjacent rack options.

  2. 02

    Power Infrastructure

    Redundant power with N+1 UPS, dual utility feeds, and diesel generators. 2kW–20kW+ per rack with A+B feeds and metered billing transparency.

  3. 03

    Precision Cooling

    Hot/cold aisle containment with N+1 redundancy. Temperature 18–27°C and humidity 40–60% RH per ASHRAE guidelines. PUE 1.15–1.30.

  4. 04

    Physical Security

    Biometric + PIN access, mantrap entry, 24/7 CCTV with 90-day retention, and on-site security personnel. Multi-layer protection 24/7.

  5. 05

    Connectivity

    Carrier-neutral with 20+ providers. AWS, Azure, and GCP direct connect, private peering, and diverse fibre entry points.

  6. 06

    Same-Building Remote Hands

    Our own engineers—not third-party staff—with physical access in under 5 minutes during business hours. No per-incident fees, no waiting.

Certified for Regulated Industries

Built to the standard your auditor expects

Financial services, health, and government contractors face non-negotiable compliance obligations. Here's how our facilities line up.

Uptime Institute tier levels

Tier I
Uptime
99.671%
Max downtime
28.8 hrs/year
Redundancy
None (N)
Suitable for
Dev, test, non-critical workloads
Tier II
Uptime
99.741%
Max downtime
22 hrs/year
Redundancy
Partial (N+1)
Suitable for
Small businesses, some redundancy
Tier IIIOur standard
Uptime
99.982%
Max downtime
1.6 hrs/year
Redundancy
Full (N+1)
Suitable for
Business-critical, finance, healthcare
Tier IV
Uptime
99.995%
Max downtime
26 min/year
Redundancy
Full (2N)
Suitable for
Mission-critical, zero-downtime

APRA CPS 234 alignment

ISO 27001SOC 2 Type IIPCI DSSNABERS

Financial services, insurance, and superannuation organisations must meet APRA's information security standard. Our partner facilities are designed for regulated industries from day one.

  1. 01

    Information Security Capability

    Tier III/IV facilities with ISO 27001 certification and dedicated security teams.

  2. 02

    Policy Framework

    Data centre security policies aligned with APRA requirements and available for audit.

  3. 03

    Data Sovereignty

    Australian-based facilities ensuring data remains within Australian jurisdiction.

  4. 04

    Third-Party Management

    SOC 2 Type II certified facilities with regular audit reports.

  5. 05

    Incident Management

    24/7 monitoring with incident notification procedures meeting 72-hour requirements.

  6. 06

    Testing & Assurance

    Regular penetration testing, vulnerability assessments, and business continuity testing.

Frequently asked questions

Ready to leave the server room behind?

Tell us your rack space and power requirements—we'll provide options including same-building remote hands. Want to see it first? We'll walk you through Interactive Port Melbourne and show you our office upstairs.

Request a Quote

Facility tours available · No obligation